Filters

RCBO

RCBO stands for 'Residual Current Breaker with Over-Current'. It protects against two types of faults and in essence combines the functionality of an MCB and RCD, which allows for the protection of both smaller and larger electrical items.

We supply a range of RCBO consumer units, including:

32A 1 Pole Type B

20A 1 Pole Type C

16A 1 Pole + Neutral Type 6

40A 1 Pole + Neutral Type A

Shop RCBOs today and get free UK delivery on orders over £50 (excluding VAT).

Show details for  20A RCBO, 1 Pole + Neutral, B Curve, Type A, 10kA, Acti9 Range

20A RCBO, 1 Pole + Neutral, B Curve, Type A, 10kA, Acti9 Range

A9D31820
£105.84 Inc VAT£88.20 Ex VAT
Priced per 1
Show details for  20A RCBO, 1 Pole + Neutral, B Curve, Type A, 10kA

20A RCBO, 1 Pole + Neutral, B Curve, Type A, 10kA

EP1PD-RCBO-B20
£20.60 Inc VAT£17.17 Ex VAT
Priced per 1
Show details for  20A RCBO, 1 Pole + Neutral, B Curve, Type A, 10kA

20A RCBO, 1 Pole + Neutral, B Curve, Type A, 10kA

RTA102030B
£36.37 Inc VAT£30.31 Ex VAT
Priced per 1
Show details for  20A RCBO with AFDD, 1 Pole + Neutral, B Curve, Type A, 6kA

20A RCBO with AFDD, 1 Pole + Neutral, B Curve, Type A, 6kA

EP-AFDD-B6-20/30
£114.76 Inc VAT£95.63 Ex VAT
Priced per 1
Show details for  20A Miniature RCBO, 1 Pole + Switched Neutral, B Curve, Type A, 6kA

20A Miniature RCBO, 1 Pole + Switched Neutral, B Curve, Type A, 6kA

NHXS1B20
£31.99 Inc VAT£26.66 Ex VAT
Priced per 1
Show details for  20A Miniature RCBO, 1 Pole + Switched Neutral, B Curve, Type A, 6kA

20A Miniature RCBO, 1 Pole + Switched Neutral, B Curve, Type A, 6kA

61/BM2030
£33.06 Inc VAT£27.55 Ex VAT
Priced per 1
Show details for  20A Compact RCBO, 1 Pole, B Curve, Type A, 6kA

20A Compact RCBO, 1 Pole, B Curve, Type A, 6kA

ERS1R620A-N
£26.90 Inc VAT£22.42 Ex VAT
Priced per 1

20A Bi-Directional RCBO, 1 Pole + Neutral, C Curve, Type A, 6kA

EP1P-RCBO-C20-BD
£18.35 Inc VAT£15.29 Ex VAT
Priced per 1
Show details for  20A Bi-Directional RCBO, 1 Pole + Neutral, B Curve, Type A, 6kA

20A Bi-Directional RCBO, 1 Pole + Neutral, B Curve, Type A, 6kA

EP1P-RCBO-B20-BD
£18.35 Inc VAT£15.29 Ex VAT
Priced per 1
Show details for  20A AFDD RCBO, 1 Pole + Neutral, C Curve, Type A, 6kA

20A AFDD RCBO, 1 Pole + Neutral, C Curve, Type A, 6kA

EPD-AFDD-C6-20/30
£117.12 Inc VAT£97.60 Ex VAT
Priced per 1
Show details for  20A AFDD RCBO, 1 Pole + Neutral, B Curve, Type A, 6kA

20A AFDD RCBO, 1 Pole + Neutral, B Curve, Type A, 6kA

EPD-AFDD-B6-20/30
£117.12 Inc VAT£97.60 Ex VAT
Priced per 1
Show details for  20A AFDD RCBO, 1 Pole + Neutral, B Curve, Type A, 6kA

20A AFDD RCBO, 1 Pole + Neutral, B Curve, Type A, 6kA

AFDD062030B
£127.52 Inc VAT£106.27 Ex VAT
Priced per 1
Show details for  16A RCBO, Single Pole + Neutral, B Curve, Type A, 6kA

16A RCBO, Single Pole + Neutral, B Curve, Type A, 6kA

NHXSBS1B16
£54.56 Inc VAT£45.47 Ex VAT
Priced per 1
Show details for  16A RCBO, 1 Pole, C Curve, Type A, 10kA

16A RCBO, 1 Pole, C Curve, Type A, 10kA

ADA166U
£49.27 Inc VAT£41.06 Ex VAT
Priced per 1
Show details for  16A RCBO, 1 Pole, C Curve, Type A, 10kA

16A RCBO, 1 Pole, C Curve, Type A, 10kA

EMCH116R30C
£63.98 Inc VAT£53.32 Ex VAT
Priced per 1
Show details for  16A RCBO, 1 Pole, B Curve, Type AC, 10kA

16A RCBO, 1 Pole, B Curve, Type AC, 10kA

ERS1R1016B
£17.50 Inc VAT£14.58 Ex VAT
Priced per 1
Show details for  16A RCBO, 1 Pole, B Curve, Type A, 6kA

16A RCBO, 1 Pole, B Curve, Type A, 6kA

ADA316G
£19.44 Inc VAT£16.20 Ex VAT
Priced per 1
Show details for  16A RCBO, 1 Pole, B Curve, Type A, 30mA, 10kA

16A RCBO, 1 Pole, B Curve, Type A, 30mA, 10kA

ADB416U
£63.65 Inc VAT£53.04 Ex VAT
Priced per 1
Show details for  16A RCBO, 1 Pole + Solid Neutral, B Curve, Type A, 6kA

16A RCBO, 1 Pole + Solid Neutral, B Curve, Type A, 6kA

RTA061630B
£17.04 Inc VAT£14.20 Ex VAT
Priced per 1
Show details for  16A RCBO, 1 Pole + Neutral, C Curve, Type A, 6kA

16A RCBO, 1 Pole + Neutral, C Curve, Type A, 6kA

EP1P-RCBO-C16
£18.35 Inc VAT£15.29 Ex VAT
Priced per 1
Show details for  16A RCBO, 1 Pole + Neutral, C Curve, Type A, 10kA, Acti9 Range

16A RCBO, 1 Pole + Neutral, C Curve, Type A, 10kA, Acti9 Range

A9D05816
£111.05 Inc VAT£92.54 Ex VAT
Priced per 1
Show details for  16A RCBO, 1 Pole + Neutral, C Curve, Type A, 10kA, Acti9 Range

16A RCBO, 1 Pole + Neutral, C Curve, Type A, 10kA, Acti9 Range

A9D11816
£105.84 Inc VAT£88.20 Ex VAT
Priced per 1
Show details for  16A RCBO, 1 Pole + Neutral, C Curve, Type A, 10kA, Acti9 Range

16A RCBO, 1 Pole + Neutral, C Curve, Type A, 10kA, Acti9 Range

SEE116C03
£58.78 Inc VAT£48.98 Ex VAT
Priced per 1
Show details for  16A RCBO, 1 Pole + Neutral, C Curve, Type A, 10kA

16A RCBO, 1 Pole + Neutral, C Curve, Type A, 10kA

RTA101630C
£36.37 Inc VAT£30.31 Ex VAT
Priced per 1

FAQs

How does an RCBO work?

RCBOs provide residual current protection and overcurrent protection in a single unit, serving as a combination of a residual current device (RCD) and a miniature circuit breaker (MCB).

They work by monitoring the flow of electrical current in electrical circuits, detecting earth leakage or overcurrent. If an earth leakage fault is detected, the RCBO will quickly trip the circuit, preventing electric shocks and other potential dangers.

What are the advantages of using an RCBO?

Safety
RCBOs provide both residual current protection and overcurrent protection, offering protection from electrical faults that damage people and property. RCBOs help to prevent both electrical fires and electrical shocks.

Various uses
RCBOs can be easily installed in lots of different locations and existing electrical systems, including distribution boards, consumer unit, or individual circuits making them convenient and adaptable to different applications.

Saves space
Using a single RCBO instead of separate RCDs and MCBs saves space in electrical panels or distribution boards and makes for a hassle-free way to protect an electrical system.

What is the difference between an RCBO and an MCB?

Miniature Circuit Breakers (MCBs) provide overcurrent protection but lack residual current protection. However, RCBOs offer the benefits of both MCBs and RCDs in a single device.

What is the difference between an RCBO and a RCCB?

RCBO provides dual protection by detecting both over currents and residual current faults, whereas a RCCB (Residual Current Circuit Breaker) provides short circuit protection.

It works by interrupting the flow of electricity when the current exceeds a predetermined level.

RCBOs are used in areas where extra protection against electric shocks is required, while residual current circuit breakers provide general electrical protection.

What is the difference between a RCBO and an RCD?

A RCD (Residual Current Device) is solely focused on detecting and quickly disconnecting the power supply when it detects a residual current fault, which can help prevent electric shocks.

An RCBO provides the same function but includes circuit breaker capabilities to protect against over currents, such as overloads and short circuits.

What are the maintenance requirements for an RCBO system?

Periodic testing is required to ensure the RCBO is functioning as it should be, including trip time and sensitivity. Regular visual inspections are also useful.

Check for any signs of damage, loose connections or signs of overheating such as discolouration and keep the unit free from dust. There should be good ventilation around the device to allow any heat to dissipate.

What are the safety features of an RCBO?

Dual protection
RCBOs combine the capabilities of an MCB and an RCD, providing both overcurrent protection and the ability to detect and rapidly disconnect the power supply in the event of residual current faults. This helps to prevent damage to surroundings and reduces the risk of electric shock.

Selective tripping
RCBOs are designed to selectively trip only the circuit experiencing a fault, allowing uninterrupted power supply to other non-faulty circuits.

This feature ensures continuity of electricity in critical areas while isolating the faulty circuit.

Wide range of sensitivities
RCBOs are available with multiple sensitivity ratings to meet specific requirements. Sensitivity is measured in milliamperes (mA) and determines the level of leakage current at which the RCBO will trip. Common sensitivity ratings include 10mA, 30mA, and 100mA, depending on the level of protection needed.

Shop RCBOs online or visit your nearest YESSS Electrical store to shop in-person.